Warning: Parameter 2 to qtranxf_postsFilter() expected to be a reference, value given in /homepages/8/d664245697/htdocs/clickandbuilds/RNEBiofarma/wp-includes/class-wp-hook.php on line 298
Orthopedics Products | RNEBiofarma.com Orthopedics Products – RNEBiofarma.com

Orthopedics Products

A complete line of products designed to provide an integrated approach to the treatment of many disorders of the Musculoskeletal System: Arthropathies, Osteoarthritis, Neuropathy, Muscle, tendon and rheumatic pains, Bone repair, Circulatory, microcirculatory, venous stasis edema.

All these products are made up of a combination of active ingredients and optimal dosages to ensure a rapid therapeutic effect.









RSS The American Journal of Orthopedics Reviews

  • Fracture Pattern and Periosteal Entrapment in Adolescent Displaced Distal Tibial Physeal Fractures: A Magnetic Resonance Imaging Study May 1, 2019
    Objectives: To investigate the fracture pattern and periosteal entrapment in adolescent distal tibial physeal fractures. Design: Retrospective case series. Setting: Level I academic trauma center. Patients/Participants: Fifty patients (10–16 years of age) with displaced Salter–Harris type II, III, or IV distal tibial physeal fractures were retrospectively reviewed. Intervention: Periosteal involvement, fracture pattern. Main Outcome Measurements: […]
  • A Novel Traction Frame for Femur Fracture Management in Developing Countries: Technique and Outcomes May 1, 2019
    Summary: Fractures of the femur have long been a major cause of morbidity and mortality in developing countries and are most frequently caused by road traffic accidents. Intramedullary nail fixation has become the gold standard of care for diaphyseal fractures of the femur. However, modern techniques require proper implants, access to imaging, and accessible operating […]
  • Biomechanical Evaluation of Interfragmentary Compression of Lag Screw Versus Positional Screw at Different Angles of Fixation May 1, 2019
    Objectives: To compare the compressive force achieved and retained with the lag versus positional screw technique at various angles of screw application. Methods: Sixty humeral sawbones were stratified into 6 groups based on the technique (lag or positional) and fixation angle (30, 60, or 90 degrees relative to the fracture plane). A sensor was placed […]
  • Salter–Harris II Ankle Fractures in Children: Does Fracture Pattern Matter? May 1, 2019
    Objectives: To determine the correlation of Salter–Harris II fracture patterns with premature physeal closure (PPC) and resultant angular deformity of the ankle. Design: Retrospective review. Setting: Cincinnati Children's Hospital Medical Center (outpatient level of care). Patients/Participants: We searched the digital ankle radiographs taken at our institution from 2001 to 2010, identifying all skeletally immature patients […]
  • Chemoprophylaxis for the Hip Fracture Patient: A Comparison of Warfarin and Low-Molecular-Weight Heparin May 1, 2019
    Objective: To compare the rates of deep venous thrombosis (DVT), rates of pulmonary embolus (PE), and complication profiles of warfarin and low-molecular-weight heparin (LMWH) in patients undergoing operative fixation of hip fractures. Design: Retrospective cohort study. Setting: Insurance-based database of more than 22 million patient records. Patients: Adult hip fracture patients who were treated operatively […]
  • Clinical Practice Guidelines for Pain Management in Acute Musculoskeletal Injury May 1, 2019
    Purpose: We aimed to produce comprehensive guidelines and recommendations that can be utilized by orthopaedic practices as well as other specialties to improve the management of acute pain following musculoskeletal injury. Methods: A panel of 15 members with expertise in orthopaedic trauma, pain management, or both was convened to review the literature and develop recommendations […]
  • Risk Factors That Influence Subsequent Recurrent Instability in Terrible Triad Injury of the Elbow May 1, 2019
    Objective: To identify risk factors associated with subsequent recurrent instability and to identify predictors of poor outcomes in terrible triad injury of the elbow. Design: Retrospective cohort study. Setting: University trauma center. Patients/Participants: Seventy-six patients who were surgically treated for terrible triad injury of the elbow. Intervention: Review of charts and standardized x-ray images before […]
  • In response May 1, 2019
    No abstract available
  • Distal Femur Locking Plates Fit Poorly Before and After Total Knee Arthroplasty May 1, 2019
    Objective: To evaluate the fit of distal femur locking plates. Secondarily, we sought to compare plate fit among patients with and without a total knee arthroplasty (TKA). Design: Retrospective. Setting: University hospital. Intervention: Standard length precontoured distal femur locking plates from 4 manufacturers were digitally templated onto each patient's pre-TKA and post-TKA radiographs. Main Outcome […]
  • Differences in the Majeed Pelvic Score Between Injured and Uninjured Patients May 1, 2019
    Objectives: To investigate the differences in the Majeed Pelvic Score (MPS) between injured and uninjured patients. Discriminative power and applicability of the MPS in elderly are also investigated, and a norm score for the MPS in the Netherlands is provided. Design: Cross-sectional cohort study. Setting: Urban level 1 trauma center. Patients/Participants: One hundred ninety-five patients […]